1500 E. Bannister Road: Building 4

This section contains documents, testing results, reports, work plans and other information related to the Bannister Environmental Program as it pertains to Building 4 at 1500 E. Bannister Road. The information is updated periodically. If you have questions regarding the information in this section, please send them to the R6 Environmental mailbox at R6environment@gsa.gov.

Jump to an individual year: 2012 2011 2010 2009 2008 2007

Click the Date to view and read/download an individual document
Date Description Results
2012
04/12/2012 Area Air and Sub-Slab Air Quarterly Monitoring Report – Building 4. Contaminant migrations may exist through perforations in the building foundation slab. However, based on identified contaminant concentrations in the indoor air and crawlspace samples collected, it does not appear that contaminants are migrating to employee-occupied spaces at concentrations above the applicable site-specific screening levels.
04/03/2012 Area Air and Sub-Slab Air Quarterly Monitoring Report – Building 4. Based on data collected during air monitoring, current building occupants do not appear to be exposed to concentrations of VOCs and PCBs in indoor air and crawlspace air.
01/20/2012 This report presents the results of area air and sub-slab air sampling conducted for the General
Services Administration (GSA) at the Bannister Federal Complex (BFC), specifically Building 4,
located at 1500 East Bannister Road, Kansas City, Missouri.
Contaminant migrations may exist through perforations in the building foundation slab.
However, based on identified contaminant concentrations identified in the indoor air and crawlspace samples collected, it does not appear that contaminants are migrating to the employee-occupied spaces located above the crawlspace at concentrations above the Site-Specific Screening Levels.
01/6/2012 The U.S. Environmental Protection Agency Area Air and Sub-Slab Air Quarterly Monitoring Report for Building- Building 4 This report presents the results of area air and sub-slab air sampling conducted at the Bannister FederalComplex, specifically Building 4. This sampling activity was the first of four planned sampling events.
2011
09/26/2011 Building 4 Crawlspace Limited Removal Activities Report. Laboratory data was reported within acceptable ranges for relevant quality control parameters (eg.
laboratory control samples, matrix spikes, etc.) and no results were rejected through Columbia
Analytical Services and Test America quality control reviews.  Internal laboratory QA/QC packages are provided with the Appendix B analytical reports.
09/02/2011 This document is the results of re-sampling of drinking water for Building 4 at Bannister. Re-sampling of drinking water for Building 4.
06/17/2011 This document pertains to Building 28, as well as Building 4. It contains a report from the General Services Administration on limited removal from Building 4 crawl space and the Building 28 sump pump. Limited removal of arsenic, lead and asbestos debris. Subsequent air testing clear.
01/07/2011 This document is the results of an Indoor Air Quality Assessment performed as part of ongoing safety and environmental management plan. CO2 readings indicate need for additional fresh air and stained ceiling tile was removed. HVAC was adjusted for fresh air.
2010
  There are no documents for the year 2010.  
2009
04/08/2009 This document contains the results of Periodic Groundwater Sampling Buildings 4 and 50 at Bannister. The Environmental Protection Agency review determined that additional periodic Groundwater sampling was required. Environmental Protection Agency reviewed the PA/SI report, accepted the results but suggested some additional, limited investigation.
2008
  There are no documents for the year 2008.  
2007
05/22/2007 This document contains the results of an Indoor Air Quality test at Building 4.