Commissioning Systems Selection Matrix

The following table is used to determine which Systems and Items are to be commissioned for the various building types GSA delivers. Column 1 is the Commissioned System. Column 2 is the Item Included within that system. Columns 3 through 7 are the five major Building Types GSA provides our customers. If a dot appears in the box under the building type, then the item in column 2 must be commissioned for that building type.

Commissioned
System
Items
Included
Federal
Office
Building
(FOB)
Border
Station
Courthouse Laboratory Data
Center
Building Envelope Walls (vapor barriers, weeps, building joints)

 •

 •

 •

 •

 •

  Windows

 

 •

 

 •

 

 •

 

 •

 

 •

  Doors

 

 •

 

 •

 

 •

 

 •

 

 •

  Roofing

 

 •

 

 •

 

 •

 

 •

 

 •

  Special arch. elements (dome, cornice, etc.)

 

 •

 

 •

 

 •

 

 •

 

 •

  Envelope (blast, hurricane, thermal, infiltration)

 

 •

 

 •

 

 •

 

 •

 

 •

Plumbing System Cleaning/flushing water systems 

 

 •

 

 •

 

 •

 

 •

 

 •

  Cleaning/flushing storm drainage systems  

 

 •

 

 

 •

 

 •

  Cleaning/flushing sanitary sewage systems  

 

 •

 

 

 •

 

 •

  Cleaning/flushing lab drainage systems      

 

 •

 
  Thermometers & gauges      

 

 •

 

 •

  Sump pumps and ejectors

 

 •

 

 •

 

 •

 

 •

 

 •

  Trap primers

 

 •

   

 

 •

 
  Backflow preventors/relief valves

 

 •

 

 •

 

 •

 

 •

 

 •

  Water heaters, water coolers  

 

 •

 

 

 •

 
  Domestic water booster pumps

 

 •

 

 •

 

 •

 

 •

 

 •

  Vibration isolation

 

 •

 

 

 •

 

 •

 

 •

  Lab waste neutralization      

 

 •

 
  High purity water system      

 

 •

 
  Special gas manifolds      

 

 •

 
  Vacuum air system      

 

 •

 
  Compressed air systems      

 

 •

 
  Emergency shower / eyewashes  

 

 •

 

 

 •

 
  Deionized water system      

 

 •

 
  Fuel oil / gas systems

 

 •

 

 •

 

 •

 

 •

 

 •

  Irrigation systems      

 

 •

 
  Water filtration (General Use)      

 

 •

 

 •

  Showers/Lavs/Toilets

 

 •

 

 •

 

 •

 

 •

 

 •

Heating, Ventilating and Air Conditioning (HVAC) Thermometers & gauges  

 

 •

 

 

 •

 

 •

  Vibration isolation  

 

 •

 

 

 •

 

 •

  Steam condensate systems

 

 •

 

 •

 

 •

 

 •

 

 •

  Hot water heating systems

 

 •

 

 •

 

 •

 

 •

 

 •

  Computer room air conditioning units

 

 •

 

 •

 

 •

 

 •

 

 •

  Chemical water treatment systems

 

 •

 

 •

 

 •

 

 •

 

 •

  Liquid chillers

 

 •

 

 •

 

 •

 

 •

 

 •

  Cooling towers

 

 •

 

 •

 

 •

 

 •

 

 •

  Condenser water system

 

 •

 

 •

 

 •

 

 •

 

 •

  Chilled water system

 

 •

 

 •

 

 •

 

 •

 

 •

  Air terminal unit system/VAV units

 

 •

 

 •

 

 •

 

 •

 

 •

  Humidifiers      

 

 •

 

 •

  Duct silencers    

 

 •

 

 •

 
  Fire and smoke/fire dampers

 

 •

 

 •

 

 •

 

 •

 

 •

  Variable speed drives

 

 •

 

 •

 

 •

 

 •

 

 •

  Air distribution systems

 

 •

 

 •

 

 •

 

 •

 

 •

  Exhaust air systems

 

 •

 

 •

 

 •

 

 •

 

 •

  Laboratory fume hoods      

 

 •

 

Back to Top

Commissioning Systems Selection Matrix (continued)
Commissioned
System
Items Included Federal
Office
Building
(FOB)
Border
Station 
Courthouse  Laboratory  Data
Center
Automatic Temperature Control System (ATC) Component FPT and calibration

 

 •

 

 •

 

 •

 

 •

 

 •

  Control air supply

 

 •

 

 •

 

 •

 

 •

 

 •

  Air terminal units, non lab

 

 •

 

 •

 

 •

 

 •

 

 •

  Air terminal, lab supply/fume exhaust      

 

 •

 
  Sequence control, AHU 100% OSA

 

 •

 

 •

 

 •

 

 •

 

 •

  Sequence control, EAHU

 

 •

 

 •

 

 •

 

 •

 

 •

  Sequence control, AHU, H&V

 

 •

 

 •

 

 •

 

 •

 

 •

  Sequence control, exhaust air fans

 

 •

 

 •

 

 •

 

 •

 

 •

  Sequence control, differential bypass valve

 

 •

 

 •

 

 •

 

 •

 

 •

  Sequence control, air terminal units, CV

 

 •

 

 •

 

 •

 

 •

 

 •

  Sequence control, air terminal units, VAV/CV

 

 •

 

 •

 

 •

 

 •

 

 •

  Sequence control, air terminal units, VAV

  

 •

  

 •

  

 •

  

 •

  

 •

  Sequence control heat exchanger

  

 •

  

 •

  

 •

  

 •

  

 •

  Sequence control, variable speed pumps

  

 •

  

 •

  

 •

  

 •

  

 •

  Sequence control, cabinet unit heaters      

  

 •

  

 •

  Sequence control, condenser water system

  

 •

  

 •

  

 •

  

 •

  

 •

  Sequence control, steam humidifiers

  

 •

 

  

 •

  

 •

  

 •

  Sequence control, water heaters

  

 •

  

 •

  

 •

  

 •

  

 •

  Sequence control, heating coils/radiant panels

  

 •

  

 •

  

 •

  

 •

  

 •

  Sequence control, labs with VAV fume hoods      

  

 •

 
  Sequence control, condenser water filters

  

 •

  

 •

  

 •

  

 •

  

 •

  Sequence control, steam generator

  

 •

  

 •

  

 •

 

 •

  

 •

  Graphic display

  

 •

  

 •

  

 •

  

 •

  

 •

  Trend logs

  

 •

  

 •

  

 •

  

 •

  

 •

  Status review screens, checks & alarming

 

 •

  

 •

  

 •

  

 •

  

 •

  Network communication

  

 •

  

 •

  

 •

  

 •

  

 •

Electrical Systems Electrical primary voltage system

  

 •

  

 •

  

 •

  

 •

  

 •

  Service switchgear

  

 •

  

 •

  

 •

  

 •

  

 •

  Emergency power system  

  

 •

  

 •

  

 •

  

 •

  Generators

  

 •

  

 •

  

 •

  

 •

  

 •

  Lighting controls (scheduled / occupancy sensors)

  

 •

  

 •

  

 •

  

 •

 
  Daylight dimming controls

  

 •

  

 •

  

 •

  

 •

 
  Switchboards

  

 •

  

 •

  

 •

  

 •

  

 •

  Distribution panel boards  

  

 •

 

  

 •

 
  Transformers  

  

 •

 

  

 •

 
  Motor control centers  

  

 •

 

  

 •

  

 •

  Power monitoring & metering

  

 •

  

 •

  

 •

  

 •

  

 •

  Transient voltage surge suppressors

  

 •

  

 •

 

  

 •

  

 •

  Variable speed drives

  

 •

  

 •

  

 •

  

 •

  

 •

  Grounding & ground fault systems  

  

 •

 

  

 •

  

 •

  Overcurrent protective devices  

  

 •

 

  

 •

  

 •

  Low voltage busway  

  

 •

 

  

 •

  

 •

  Thermographic Survey

  

 •

  

 •

  

 •

  

 •

  

 •

  Electronic calendaring or directory      

  

 •

 
  White sound system

  

 •

   

  

 •

 
  Data & communication system

  

 •

  

 •

  

 •

  

 •

  

 •

  Paging system

  

 •

  

 •

 

  

 •

 
  Local devices (switches and outlets)

  

 •

  

 •

  

 •

  

 •

  

 •

Back to Top

Commissioning Systems Selection Matrix (continued)
Commissioned
System
Items
Included
Federal
Office
Building
(FOB) 
Border
Station  
Courthouse Laboratory  Data
Center 
Life Safety Systems Fire suppression / protection systems

  

 •

  

 •

  

 •

  

 •

  

 •

  Egress pressurization / Atrium smoke purge

  

 •

  

 •

  

 •

  

 •

  

 •

  Fire alarm

  

 •

  

 •

  

 •

  

 •

  

 •

  Fire suppression / protection systems

  

 •

  

 •

  

 •

  

 •

  

 •

  Emergency lighting systems

  

 •

  

 •

  

 •

  

 •

  

 •

  General egress (panic hardware, etc.)

  

 •

  

 •

  

 •

  

 •

  

 •

  Elevator recall

  

 •

  

 •

  

 •

  

 •

  

 •

Security Access Control

  

 •

  

 •

  

 •

  

 •

  

 •

  Alarm monitoring

  

 •

  

 •

  

 •

  

 •

  

 •

  Surveillance

  

 •

  

 •

  

 •

  

 •

  

 •

Specialties Elevators

  

 •

  

 •

  

 •

  

 •

  

 •

  Escalators

  

 •

 

  

 •

  

 •

 
  Cold rooms      

  

 •

 
  Kitchen/food service

  

 •

 

  

 •

  

 •

 
  Audio visual systems

  

 •

 

  

 •

  

 •

 
  Automatic doors

  

 •

   

  

 •

 
  Dark rooms

  

 •

   

  

 •

 
  Oil / water separators

  

 •

  

 •

  

 •

  

 •

  

 •

  Detention Mains  

  

 •

 

  

 •

 