Vacuum Insulated Panels for Roofing Applications

Vacuum-Insulated Panels (VIPs) offer very effective insulation (achieving an R-value of 50) within a very slim profile. That profile makes them useful on roofs where adding bulk can be expensive.

Researchers found that VIPs were robust if carefully installed. VIPs and R-50 insulation can offer favorable payback in one-story buildings in regions with extreme climates and high utility costs.

View full-size infographic. [PDF - 235 KB]

GPG Findings 011, Vacuum Insulated Panels In Roofing Applications. Opportunity: How much energy is used for heating, ventilation and air conditioning (HVAC) in U.S. office buildings? 37% of energy goes to HVAC. A large percentage routinely escapes through the building envelope. Technology: How do VIPs save energy? R-50 insulation value within a thin profile, 1” compared to 15” for conventional. Measurement and Verification: Where did M and V occur? Oak Ridge National Laboratory evaluated the performance of a VIP retrofit at the US Post Office and Courthouse in Camden, New Jersey. Results: How did VIPs perform in M and V? 8-10% energy savings when compared to code-compliant roofs. Robust performance with proper planning. Savings for R-50 greatest in single-story buildings in extreme climates. Deployment: Where does M and V recommending deploying VIPs? Retrofits where R-50 is required and installing conventional insulation necessitates costly alterations. [PDF - 235 KB]


Reference above to any specific commercial product, process or service does not constitute or imply its endorsement, recommendation or favoring by the United States Government or any agency thereof.

Last Reviewed: 2023-01-06